27 changes: 27 additions & 0 deletions docs/deferred_defects.md
Original file line number Diff line number Diff line change
Expand Up @@ -201,3 +201,30 @@ without renumbering.

**Found during:** #1098 step 4, running the project-file and NeXus reduction tests together.
**Why it is deferred.** A test defect outside #1098, and CI is not affected.

- **DD-34**, 2026-11-20: a project file that reduction writes to a new path has no instrument geometry, so NXstress
cannot be written from it.
- **Cause:** `ReductionApp.save_diffraction_data` (`pyrs/core/powder_pattern.py`) opens a new output file in
`OVERWRITE` mode and writes the sample logs, wavelength, reduction record and patterns, but never calls
`write_instrument_geometry`. Only `NeXusConvertingApp.save` (`pyrs/core/nexus_conversion.py`) writes it.
- **Where it bites:** Manual Reduction's `reduce_hidra_workflow` (`pyrs/interface/manual_reduction/pyrs_api.py`)
converts in memory and saves through that call, so its output files carry no `geometry setup`.
- **Failure:** loading such a file gives a workspace without an instrument setup, and NXstress's instrument group
cannot be written from it.
- **Workaround in the tests:** `tests/integration/test_nxstress_calibration.py` adds the geometry to the reduced
file itself (`write_instrument_geometry`) before loading it.
- **Fix:** have `save_diffraction_data` write the workspace's instrument geometry when it creates a new file.

**Found during:** #1099, writing the real-data NXstress test (T1).
**Why it is deferred.** It predates #1099 and changes what reduction writes, which needs its own approval.

- **DD-36**, 2026-11-24: a refused NXstress write can leave a partial file. `NXstress(path, "w")` creates and opens
the file when its `with` block starts (`NXstress.__enter__`), so a write refused after that -- a workspace without
a `2theta` log, mixed calibrations, a missing field -- closes an incomplete file (about 800 bytes) at `path`
instead of leaving none. GUI saves are not affected: they write a temporary sibling and replace the destination
only on success (`gui_helper.write_nxstress_or_report`, see DD-10); scripts and code that use `NXstress`
directly are.

**Found during:** the test review of #1132 (#1099), which adds refusals during a write.
**Why it is deferred.** It predates #1099. The fix -- `NXstress` writing a temporary file and renaming it on
success -- changes how every NXstress write handles its file, outside the scope of #1132.
78 changes: 75 additions & 3 deletions docs/ground_truths.md
Original file line number Diff line number Diff line change
Expand Up @@ -3081,11 +3081,12 @@ becomes this check), `PyRsCore`, and the calibration GUI's "From file…" overla
- **The chain is `DetectorModel`'s order, innermost first** (`detector_model.CALIBRATION_TRANSFORMATIONS`,
built by `transformation_chain`): shift_x, shift_y, rotation_z, rotation_y, rotation_x (R = Rx·Ry·Rz, so Rz
acts first), arm_length, shift_z, two_theta_0 (about Y), arm_rotation (about Y; stored as 0, because the arm
angle belongs to each sub-run). Each value is float64 in m or deg, right-handed, in the PyRS frame (+Z beam,
angle belongs to each sub-run — **superseded by #1099:** the calibration file's chain now ends at
two_theta_0, see *NXstress detector chain is the calibration file's*). Each value is float64 in m or deg, right-handed, in the PyRS frame (+Z beam,
+Y up), with `<name>_errors` beside it (the JSON's -1 / -2 codes). The reader checks every transformation's
type, vector, units and `depends_on` against this chain, and refuses (`ValueError`) a file that would be
applied differently. It also checks that the detector's `depends_on` starts the chain at `shift_x`, that
`arm_rotation` is 0, and that the pixel offsets are PyRS's layout (`DetectorModel.local_positions`:
applied differently. It also checks that the detector's `depends_on` starts the chain at `shift_x` (the
`arm_rotation` = 0 check was dropped with the field, #1099), and that the pixel offsets are PyRS's layout (`DetectorModel.local_positions`:
X decreasing with `index_0`, Y increasing with `index_1`). The old NXstress chain, with 2θ₀ about X, would
be refused. One-element string arrays and shape-(1,) values, as other tools write them, are read. Also
refused (CodeRabbit review): a transformation with a non-zero NeXus `offset` (`DetectorModel` applies none),
Expand Down Expand Up @@ -3650,6 +3651,77 @@ the Docs: `docs/user/source`), so nothing caught it.
- **User docs:** `docs/user/source/conf.py` still uses plain `Mock` objects. It builds, because it documents
nothing they replace.

## NXstress detector chain is the calibration file's (2026-11-20, #1099)

- **Before:** NXstress wrote its own detector chain, and it did not place pixels where reduction does.
- **Order:** entering at the detector's `depends_on` (the innermost transformation, the NeXus rule) gave
two_theta_zero → Rz → Ry → Rx → distance → z → y → x. That does not match `DetectorModel.lab_positions`:
the rotation order (Rz → Ry → Rx) agrees, but 2θ₀ was applied first instead of after the arm length, and
the x/y shifts were applied last instead of before the rotations.
- **2θ₀ axis:** about X.
- **Arm angle:** missing.
- **Impact:** nothing in PyRS read the chain (`instrumentFromNexus` reads the values by name), so reduction was
unaffected; only external NeXus tools were misled.
- **Now:** `calibration_nexus.detector_transformations`, shared with the calibration file, writes it:
- shift_x, shift_y, rotation_z, rotation_y, rotation_x, arm_length, shift_z, two_theta_0 (about Y), arm_rotation;
- each calibration parameter with its `<name>_errors`;
- the detector's `depends_on` is `transformations/shift_x`.
- **The calibration file has no arm angle (user decision, #1132 review):** it holds the calibration parameters
only, and PyRS builds the instrument from them and each sub-run's arm angle. Its chain ends at `two_theta_0`
(`depends_on = "."`); only NXstress writes `arm_rotation`. The reader checks the chain up to `two_theta_0`
and skips an `arm_rotation` entry if a file has one (no check, no refusal). No calibration NeXus files had
been written before this, so the old layout (`arm_rotation` = 0) needs no support. Replaces the old shared
note, which told calibration files they held −(DAS arm 2theta).
- **Arm angle:** `arm_rotation` holds one value per scan point, −(the `2theta` log), and grows on append. Data
without a `2theta` log are refused (user decision, #1132 review G9): without the arm angle the detector cannot
be placed, so the write fails, naming the workspace. (It used to write NaN.)
- **Calibration defaults and L2 (user decisions, #1132 review G9):** a default calibration parameter is 0 with
error −1 (the nominal calibration), so a calibration JSON missing a parameter reads as the default
(`check_calibration_dictionary`, unchanged). L2 is part of the calibration and is to be compared by its hash
(#1141); until then it is compared for exact equality.
- **Arm length (user decision):** a single value, the runs' `L2` log when present (the one reduction uses), else
the instrument's. An entry whose L2 differs between scan points is refused.
- **Errors (user decision):** those of the applied calibration. −1 where none are known.
**Superseded (user decision, #1132 review G3; implemented by #1141):** −1 is the default (not refined, as
in the nominal calibration) and −2 an unknown error, so an error that is not known is written as −2. Until
#1141 lands, this PR still writes −1.
- **NXstress used to write the nominal detector for real data.** A workspace loaded from a project file never
got the calibration reduction applied: only FitCalibration and NXstress read-back set its shift. So every
NXstress file written from reduced data said `calibrated = False`.
- **Fix:** loading now keeps the file's recorded calibration (shift and errors, `get_recorded_calibration()`),
and NXstress writes that.
- **Kept apart from `get_detector_shift()` on purpose:** `ReductionApp` applies the workspace's shift
whenever no calibration file is given. Setting the shift would have made reducing a project file again,
without a calibration file, silently switch from the nominal geometry to the recorded one.
- **No backward compatibility (user decision, #1132 review):** NXstress and the NeXus calibration file are new
formats and may break old layouts. `instrumentFromNexus` reads only the current names (`shift_*`,
`arm_length`, `two_theta_0`); an entry written before #1099 (`translation_*`, `distance`, `two_theta_zero`, no
`arm_rotation`) is not supported, and an append to one is refused for its missing `arm_rotation`
("write a new entry"). This replaces the earlier decision to read old entries.
- **A missing field is a corrupt file (user decision, #1132 review, G9):** NXstress and the calibration file
always write every field, so a missing one means a failed write or a corrupt file. `instrumentFromNexus`
refuses it (`RuntimeError` naming the field), for the pixel layout, the `calibrated` flag, `arm_length`, each
calibration value and the wavelength. Before, a missing field read as 0.0: a calibration parameter silently
became 0, and a missing arm length failed with a message that did not name it.
- **Tested:** applied independently of `DetectorModel`, the written chain reproduces `lab_positions` at every scan
point to 1e-12 m.
- **The chain is a self-consistent choice (user decision, #1132 review R5):** PyRS defines the detector's
placement (`DetectorModel.lab_positions`, `CALIBRATION_TRANSFORMATIONS`), and the calibration refines its
parameters in that same model; NXstress and the calibration file write exactly that chain. It is not grounded in
an external reference (unlike the sample chain, which follows He, *Two-Dimensional X-ray Diffraction*, ch. 8.3),
and needs none: the check that matters is that the written chain places pixels where reduction does.
- **Errors survive a round trip.** Reading an NXstress entry back sets both the workspace's shift and its recorded
calibration with the entry's errors (`_Instrument.shiftErrorFromNexus`), so writing it again keeps them. Before
the code-review fix they came back as −1.
- **Which errors are written:** the workspace's own shift, with the recorded errors only when the recorded shift is
that same shift; with no shift, the recorded calibration. Errors are never lent to a different shift.
- **Mixed files record none.** Appending a project file reduced with another calibration (or none) clears the
recorded calibration, with a warning, so NXstress does not label every scan point with the first file's.
- **An unreadable record is optional:** it is warned about, the recorded calibration stays None, and the data load.
- **Fresh reductions carry no geometry (DD-34):** a project file that reduction writes to a new path has no
instrument geometry, so NXstress cannot be written from it until the geometry is added. See
[deferred_defects.md](deferred_defects.md).

## Calibration study: what the measurement conditions and the settings change (2026-11, #1097)

A study with no production change: ring calibrations (`calibrate_rings`, default settings unless stated) of 11 powder runs
Expand Down
4 changes: 2 additions & 2 deletions pyrs/core/detector_model.py
Original file line number Diff line number Diff line change
Expand Up @@ -358,13 +358,13 @@ def transformation_chain(

Applied in order to a pixel's uncalibrated position (:meth:`DetectorModel.local_positions`), the chain
gives its lab position, as :meth:`DetectorModel.lab_positions` does: the one description of the
detector's geometry, for the NeXus calibration file (and, later, NXstress output).
detector's geometry, for the NeXus calibration file and NXstress output.

Args:
calibration: Detector shift, rotations and 2theta_0, or None for the nominal geometry.
arm_length: Sample-to-detector distance L2 (m).
arm_two_theta: Arm angle in the Mantid/PyRS convention (``-get_detector_2theta()``); a calibration
file stores 0, since the arm angle belongs to each sub-run, not to the calibration.
file omits the arm angle, which belongs to each sub-run.

Returns:
The transformations of :data:`CALIBRATION_TRANSFORMATIONS`, with their values.
Expand Down
54 changes: 54 additions & 0 deletions pyrs/core/workspaces.py
Original file line number Diff line number Diff line change
Expand Up @@ -12,6 +12,11 @@
_logger = logging.getLogger(__name__)


def _shift_values(recorded):
"""The seven calibration values of a recorded calibration, to compare two (#1099); None for none."""
return None if recorded is None else tuple(recorded[0].convert_to_dict().values())


class HidraWorkspace:
"""
This workspace is the central data structure to manage all the raw and/or processed data.
Expand Down Expand Up @@ -47,6 +52,9 @@ def __init__(self, name="hidradata"):
# instrument
self._instrument_setup = None
self._instrument_geometry_shift = None # geometry shift
# the calibration reduction applied, from a project file's record (#1099): kept apart from the shift
# above, which reduction applies when no calibration file is given (ReductionApp)
self._recorded_calibration = None

# sample logs
self._sample_logs = SampleLogs() # sample logs: [log name, sub run] = value
Expand Down Expand Up @@ -603,6 +611,34 @@ def load_hidra_project(self, hidra_file, load_raw_counts, load_reduced_diffracti
# load the wave length
self._load_wave_length(hidra_file)

# the calibration the reduction applied, as the file recorded it (#1099)
self._load_recorded_calibration(hidra_file)

def _load_recorded_calibration(self, hidra_file) -> None:
"""Keep the calibration the reduction applied (shift and errors), from the file's calibration record
(#1053, #1099). A file with no record (reduced before #1053, or never calibrated) keeps None; a record
that cannot be read is warned about and kept None, as the file must still load."""
self._recorded_calibration = self._read_recorded_calibration(hidra_file)

def _read_recorded_calibration(self, hidra_file):
"""``(shift, shift_error)`` the file's reduction applied, or None (no record, or unreadable: warned)."""
try:
record = hidra_file.read_reduction_provenance()
if record.get("source", "none") == "none" or "calibration" not in record:
return None
instrument = hidra_file.read_reduction_instrument(self._instrument_setup)
except Exception as read_err: # noqa: BLE001 - the record is optional; the data must load
self._log.warning(f"applied calibration could not be read: {type(read_err).__name__}: {read_err}")
return None
if instrument.geometry_shift is None:
return None
return instrument.geometry_shift, instrument.geometry_shift_error

def set_recorded_calibration(self, shift, shift_error) -> None:
"""Set the calibration applied to this data and its errors (#1099), e.g. as read back from NXstress;
None for none. Reduction never applies it (that is :meth:`set_detector_shift`)."""
self._recorded_calibration = None if shift is None else (shift, shift_error)

def append_hidra_project(self, hidra_file):
"""
Load HIDRA project file
Expand All @@ -628,6 +664,15 @@ def append_hidra_project(self, hidra_file):
# # load masks
# self._load_masks(hidra_file)

# the appended data must have had the same calibration applied, or none can be claimed for the whole (#1099)
appended = self._read_recorded_calibration(hidra_file)
if _shift_values(appended) != _shift_values(self._recorded_calibration):
self._log.warning(
f"{hidra_file.name} was reduced with a different calibration (or none) than the data before it; "
"the combined data records no applied calibration"
)
self._recorded_calibration = None

def get_detector_mask(self, is_default, mask_id=None):
"""Get detector mask

Expand Down Expand Up @@ -665,6 +710,15 @@ def get_detector_shift(self):
"""
return self._instrument_geometry_shift

def get_recorded_calibration(self):
"""The calibration a reduction applied to this data, as its project file recorded it (#1099).

Returns:
``(shift, shift_error)`` (``DENEXDetectorShift``; the error None if not recorded), or None if the file
records no calibration. Unlike :meth:`get_detector_shift`, reduction never applies it.
"""
return self._recorded_calibration

def get_reduced_diffraction_data_set(self, mask_id=None):
"""Get reduced diffraction data set including 2theta and intensities

Expand Down
2 changes: 2 additions & 0 deletions pyrs/utilities/NXstress/NXstress.py
Original file line number Diff line number Diff line change
Expand Up @@ -1018,6 +1018,8 @@ def _workspaceFromNexus(cls, entry, rows, default_mask, mask_dict) -> HidraWorks
ws.set_instrument_geometry(geometry)
if shift is not None:
ws.set_detector_shift(shift)
# its errors too, so a workspace read back and written again keeps them (#1099)
ws.set_recorded_calibration(shift, _Instrument.shiftErrorFromNexus(entry[GROUP_NAME.INSTRUMENT]))
ws.set_masks_from_dict(default_mask, mask_dict)

# Read raw counts if present
Expand Down
Loading
Loading