set chemical hardnesses for point charges in the C API #920
To obtain point charge like behaviour for the partial charges the chemical hardness can be set to a large value. This can be done by specifying the chemical hardnesses in the fifth column instead of giving an element symbol. For this setup the water_4.pc would look like
Describe the solution you'd like
There is another function that can set chemical hardness.
Describe alternatives you've considered
Or there is a virtual element whose chemical hardness is 99.
If possible state how you can assist in providing data or code to to implement the feature
I can assist in it, but the stable API needs a decision.
Additional context
Indeed, it's unclear how to set the element of the point charge for 4-site water (TIP4P). It has an extra point that is not a real atom.