Skip to content

About

Twisted projection imaging sequence implemented using the Pulseq framework.

Resources

Stars

2 stars

Watchers

0 watching

Forks

Latest commit

 

History

14 Commits

Folders and files

Repository files navigation

TPI Pulseq Compiler and Reconstruction

Interactive Pulseq compiler and reconstruction pipeline for Twisted Projection Imaging (TPI), targeting sodium (23Na) MRI with support for proton (1H) acquisitions. Implements the constant-polar-angle cone trajectory of Boada et al. (1997).

Note: The compiler is built for pulseq version 1.5.x

Repository contents

  • TPI_UI.m — interactive GUI: parameter entry, one-click compile, k-space/gradient/slew diagnostics, and .seq export.
  • tpi_compile_advanced.m — compute-only sequence compiler consumed by the UI (no plotting side effects; returns a struct for programmatic use).
  • design_tpi_projection.m — single-projection (radial ramp + twist + ramp-down) gradient waveform design for one cone.
  • calc_cone_distribution.m — Nyquist-based ring/spoke distribution across the k-space sphere, with optional undersampling.
  • compute_slew_vs_cone_angle.m — theoretical slew-rate sweep across all polar angles, used for hardware-feasibility diagnostics.
  • TPI_Recon.m — example non-Cartesian reconstruction pipeline for TPI raw data (NUFFT gridding + density compensation, Hamming filtering).
  • utils/ — small standalone helpers used by TPI_Recon.m

Dependencies

Dependency Purpose
Pulseq for MATLAB Sequence design, gradient/ADC/RF construction, k-space calculation, and .seq export
nufft_3d 3D non-uniform FFT used by TPI_Recon.m for gridding TPI k-space data
mapVBVD Raw data loading (Siemens TWIX .dat format); bundled within the FID-A toolbox's inputOutput folder
MATLAB App Designer (uifigure, uigridlayout, etc.) Required for TPI_UI.m; ships with MATLAB, no separate install

Usage

Note: If you need help setting the compiler up or have any kind of questions plese contact me.

  1. Launch TPI_UI in MATLAB with Pulseq on the path.
  2. Set scanner, nucleus, geometry (FOV, matrix, TR), and TPI trajectory parameters (twist fraction p, T_read, ramp/transition modes).
  3. Click Calculate / Recompile to run tpi_compile_advanced and inspect the k-space trajectory, one-TR gradient/ADC view, and the slew-rate-vs-cone-angle diagnostic.
  4. Click Save Sequence (.seq)... to export the compiled Pulseq file.
  5. Reconstruct raw data with TPI_Recon.m, which grids the compiled trajectory via nufft_3d and applies density compensation. NOTE: Be sure nufft_3d is on the path.

⚠️ Safety notice: Always verify SAR, gradient amplitude, slew rate, and duty cycle limits on your specific scanner before executing any sequence on hardware. This code is provided "as is" without warranty of any kind.

Running without the GUI

TPI_compiler.m sets every parameter that TPI_UI.m would normally collect through the interface and calls tpi_compile_advanced.m directly. Use this for:

  • machines without a display (remote/cluster jobs),
  • scripted parameter sweeps (wrap the parameter block in a loop),
  • reproducible, version-controlled protocol definitions.

Edit the parameter block at the top, then run the script; it saves the compiled .seq file and (optionally) the k-space/slew diagnostic plots to an output/ folder. All prm fields match those documented in tpi_compile_advanced.m's header comment.

Key trajectory parameters

Parameter Description
p Twist onset fraction (k0/kmax); controls TPI scan-time efficiency vs. slew load
Tread Target effective readout time, sets gradient amplitude G_amp
ramp_mode / ramp_stretch Shape and duration margin of the Phase 1/3 |G| ramps
transition_mode / transition_stretch Optional taper of angular velocity at the Phase 1→2 boundary to reduce slew spikes
avoid_equator Excludes the exact equatorial ring (theta = 90 deg, odd NR)
undersample_factor Additional ring/spoke undersampling beyond Nyquist

Add a new nuclei or scanner

Go to tpi_compile_advanced.m and you can find the following section right at the top. Just use your hardware limits to define a new scanner or add a new nuclei with the corresponding gyromagnetic ratio. The safty margin allows you to define how much of the potential hardware limit you want to work with.

Scanner and Nulcei definition

Reference

Boada FE, Gillen JS, Shen GX, Chang SY, Thulborn KR. Fast three dimensional sodium imaging. Magn Reson Med. 1997;37(5):706-715.

Citation

Jost V, Licht C, Zehender D, Zoellner F. A fully parametric open-source Twisted Projection Imaging (TPI) implementation with Anatomically Guided Reconstruction (AGR). In: Proceedings of the 2026 ISMRM Workshop on Beyond Protons: Challenges and Advances in X-Nuclei MR, Barcelona, Spain.

Note: The undersampling factors published in the abstract will not apply to the current compiler version.

License

Copyright (C) 2026 Valentin Jost

This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License version 3 as published by the Free Software Foundation.

This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.

Note on dependencies: Pulseq is licensed under MIT, which is compatible with GPL-3.0. Any derivative works that incorporate or modify code from this repository must also be released under GPL-3.0.