Caching the workspace and warm-starts

SCS supports reusing the workspace between solves so long as the data matrices A and P do not change. After an initial solve the workspace can be updated with new b and c vectors if desired. This can substantially speed up subsequent solve times since we can cache important quantities such as the matrix factorization and the data equilibration. Moreover, SCS supports warm-starting the solver with a guess of the solution, which can significantly reduce the total number of iterations required for convergence.

The workspace also keeps the scale parameter and the per-row multipliers of adaptive_diag_scale as the previous solve left them (see :ref:`Dynamic scale updating <updating_scale>`), together with the linear system set up for them (the factorization, for a direct solver). When adaptive_scale is enabled, a later solve on the same workspace, with or without a warm-start and with or without a call to scs_update in between, therefore starts from these adapted values and not from the scale that was passed to scs_init. Only the bookkeeping of the update procedure starts again in each solve: the samples it averages and the count of iterations since the last update. So the first update in a solve is made no earlier than iteration 100, and scale_updates in the :ref:`info <info>` struct counts the updates of that solve only. One consequence is that solving the same problem twice on one workspace need not take the same number of iterations both times. To start again from the original scale, create a new workspace with scs_init.

Re-using the workspace and warm-starting can be useful, for example, when solving a sequence of related problems such as in :ref:`Model predictive control <py_mpc>` or solving for the entire regularization path in the :ref:`the Lasso <py_lasso>`.

In the :ref:`C API <c_interface>` call scs_init once to initialize the workspace, then use the scs_solve in conjunction with scs_update to solve a sequence of problems. Warm-starting can be done by setting the warm-start :ref:`setting <settings>` to True when calling scs_solve, and then including the guess of the solution in the x, y, s members of the :ref:`ScsSolution` struct, where those members correspond to the guess of the solution in the :ref:`standard form <optimality>`. SCS will initialize the solver at those points and then overwrite the :ref:`ScsSolution` struct members with the real solution at termination.

The settings that only the solve reads, such as the tolerances, max_iters and time_limit_secs, can also be changed between solves with scs_update_settings, see :ref:`update_settings`.